Project 2 · Kaisariani, Edessa
Certified Passive House in Kaisariani, Edessa
Construction supervision, heat-recovery ventilation installation and Blower Door testing of the building envelope.

The project
Designed and verified in detail.
Technical supervision focused on the airtight envelope, window connections and the mechanical ventilation system with heat recovery. The photographic record documents the air-distribution network, critical junctions and final airtightness test.
- Heat-recovery ventilation system installation
- Air-duct network development and inspection
- Airtight window-to-envelope connections
- Depressurisation and pressurisation testing at 50 Pa
Certified performance
Technical energy figures
Verified project figures confirming compliance with the Passive House Classic criteria.
Blower Door Test
Measured airtightness results
The final test recorded an average n50 value of 0.58 1/h, with 0.57 1/h under depressurisation and 0.59 1/h under pressurisation. The average airflow V50 was 229 m³/h and the air permeability q50 was 1.62 m³/(h·m²).
Project gallery
From design to verification.