Project 1 · Florina

PH X-1 · Florina's First Certified Passive House

Turnkey Passive House design and construction, with continuous monitoring of its actual energy performance.

PH X-1 · Florina's First Certified Passive House

The project

Designed and verified in detail.

PH X-1 was designed for Florina's demanding winter climate. Its high-performance envelope, thermal-bridge-free detailing, airtight connections, carefully installed windows and heat-recovery ventilation deliver exceptional comfort with very low energy demand.

  • Insulated foundations, floor slab, walls and roof
  • Continuous airtight layer using membranes and specialist tapes
  • Controlled window installation and connection testing
  • Real indoor-temperature and energy-performance monitoring

Certified performance

Technical energy figures

Heating demand9 kWh/(m²·year)
Heating load16 W/m²
Cooling & dehumidification8 kWh/(m²·year)
Cooling load12 W/m²
Excessive-humidity frequency0 %
Certified airtightnessn50 = 0,40 1/h
Renewable primary energy (PER)36 kWh/(m²·year)
Renewable-energy generation7 kWh/(m²·year)

Figures from the PH X-1 Passive House Classic certificate, issued on 30 June 2023.

Blower Door Test

Measured airtightness results

The final evaluation under depressurisation and pressurisation at 50 Pa recorded an average air-change rate n50 of 0.39 1/h, an average airflow V50 of 143 m³/h and an average envelope air permeability q50 of 0.98 m³/(h·m²).

Average n500,39 1/h
Average V50143 m³/h
Average q500,98 m³/(h·m²)

Contact

Planning a project that deserves to perform better?

Business details

Company
XK Passive House & Engineers Team E.E.
Address
6 Aristotelous & Kioutachias, Florina, Greece
Hours
Monday–Friday 09:00–13:00
Until 20:00 by appointment
Principal engineer
Konstantinos Chatzopoulos
Civil Engineer
Directions on Google Maps →
Open directions to our office →